The single no-covered XLPE-insulated aluminium cable is constituted by a compact or a non compact round conductor, composed by aluminium strands, with a cross-linked (XLPE) insulated, in black color.
Read more10mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 10 mm²
- Number of aluminium wires: 7
- Conductor diameter: 4.1 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 7.5 mm
- Approximate weight: 60 kg/km
16mm2
Nexans ref. 38693
- Packaging: Cut to length (2000m)
- Conductor cross-section: 16 mm²
- Number of aluminium wires: 7
- Conductor diameter: 4.7 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 8.2 mm
- Approximate weight: 77 kg/km
25mm2
Nexans ref. 30774
- Packaging: Cut to length (1000m)
- Conductor cross-section: 25 mm²
- Number of aluminium wires: 7
- Conductor diameter: 5.9 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 9.4 mm
- Approximate weight: 108 kg/km
35mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Number of aluminium wires: 7
- Conductor diameter: 7.0 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 10.5 mm
- Approximate weight: 140 kg/km
50mm2
Nexans ref. 30773
- Packaging: Cut to length (1000m)
- Conductor cross-section: 50 mm²
- Number of aluminium wires: 19
- Conductor diameter: 8.1 mm
- Nominal insulation thickness: 2.0 mm
- Outer Diameter: 12.5 mm
- Approximate weight: 195 kg/km
70mm2
Nexans ref. 42545
- Packaging: Cut to length (1000m)
- Conductor cross-section: 70 mm²
- Number of aluminium wires: 19
- Conductor diameter: 9.8 mm
- Nominal insulation thickness: 2.0 mm
- Outer Diameter: 14.5 mm
- Approximate weight: 260 kg/km
95mm2
Nexans ref. 26791
- Packaging: Cut to length (1000m)
- Conductor cross-section: 95 mm²
- Number of aluminium wires: 19
- Conductor diameter: 11.5 mm
- Nominal insulation thickness: 2.0 mm
- Outer Diameter: 16 mm
- Approximate weight: 340 kg/km
120mm2
Nexans ref. 39809
- Packaging: Cut to length (500m)
- Conductor cross-section: 120 mm²
- Number of aluminium wires: 37
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 18.5 mm
- Approximate weight: 440 kg/km
150mm2
Nexans ref. 39501
- Packaging: Cut to length (500m)
- Conductor cross-section: 150 mm²
- Number of aluminium wires: 37
- Conductor diameter: 14.3 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 19.5 mm
- Approximate weight: 520 kg/km
185mm2
Nexans ref. 52181
- Packaging: Cut to length (500m)
- Conductor cross-section: 185 mm²
- Number of aluminium wires: 37
- Conductor diameter: 16.0 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 21.5 mm
- Approximate weight: 635 kg/km
240mm2
Nexans ref. 43504
- Packaging: Cut to length (500m)
- Conductor cross-section: 240 mm²
- Number of aluminium wires: 37
- Conductor diameter: 18.4 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 24 mm
- Approximate weight: 805 kg/km
300mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Number of aluminium wires: 37
- Conductor diameter: 20.7 mm
- Nominal insulation thickness: 2.8 mm
- Outer Diameter: 27 mm
- Approximate weight: 1025 kg/km
400mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 400 mm²
- Number of aluminium wires: 61
- Conductor diameter: 23.4 mm
- Nominal insulation thickness: 2.8 mm
- Outer Diameter: 29.5 mm
- Approximate weight: 1280 kg/km
500mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 500 mm²
- Number of aluminium wires: 61
- Conductor diameter: 26.6 mm
- Nominal insulation thickness: 2.8 mm
- Outer Diameter: 33 mm
- Approximate weight: 1610 kg/km
Description
Description
Standards
-
ProductABNT NBR 7285/01
Application
The no-covered insulated cables are recommended for power supply circuits and power distribution in industrial, commercial and residential buildings.
Manufacturing Data
1) Conductor
Aluminium strands, class 2 stranding.
2) Insulation
Cross-linked Polyethylene (XLPE), for 90°C, black color.
Voltage Class:
0,6/1kV
Operating Temperature:
Normal operation: 90°C, Overload: 130°C, Short-circuit: 250°C
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Usage characteristics
Usage characteristics
Fire safety characteristics
Fire safety characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania