Single no-covered XLPE-insulated Aluminium Cables
Single no-covered XLPE-insulated Aluminium Cables
The single no-covered XLPE-insulated aluminium cable is constituted by a compact or a non compact round conductor, composed by aluminium strands, with a cross-linked (XLPE) insulated, in black color.
Read more10mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 10 mm²
- Number of aluminium wires: 7
- Conductor diameter: 4.1 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 7.5 mm
- Approximate weight: 60 kg/km
16mm2
Nexans ref. 38693
- Packaging: Cut to length (2000m)
- Conductor cross-section: 16 mm²
- Number of aluminium wires: 7
- Conductor diameter: 4.7 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 8.2 mm
- Approximate weight: 77 kg/km
25mm2
Nexans ref. 30774
- Packaging: Cut to length (1000m)
- Conductor cross-section: 25 mm²
- Number of aluminium wires: 7
- Conductor diameter: 5.9 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 9.4 mm
- Approximate weight: 108 kg/km
35mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Number of aluminium wires: 7
- Conductor diameter: 7.0 mm
- Nominal insulation thickness: 1.6 mm
- Outer Diameter: 10.5 mm
- Approximate weight: 140 kg/km
50mm2
Nexans ref. 30773
- Packaging: Cut to length (1000m)
- Conductor cross-section: 50 mm²
- Number of aluminium wires: 19
- Conductor diameter: 8.1 mm
- Nominal insulation thickness: 2.0 mm
- Outer Diameter: 12.5 mm
- Approximate weight: 195 kg/km
70mm2
Nexans ref. 42545
- Packaging: Cut to length (1000m)
- Conductor cross-section: 70 mm²
- Number of aluminium wires: 19
- Conductor diameter: 9.8 mm
- Nominal insulation thickness: 2.0 mm
- Outer Diameter: 14.5 mm
- Approximate weight: 260 kg/km
95mm2
Nexans ref. 26791
- Packaging: Cut to length (1000m)
- Conductor cross-section: 95 mm²
- Number of aluminium wires: 19
- Conductor diameter: 11.5 mm
- Nominal insulation thickness: 2.0 mm
- Outer Diameter: 16 mm
- Approximate weight: 340 kg/km
120mm2
Nexans ref. 39809
- Packaging: Cut to length (500m)
- Conductor cross-section: 120 mm²
- Number of aluminium wires: 37
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 18.5 mm
- Approximate weight: 440 kg/km
150mm2
Nexans ref. 39501
- Packaging: Cut to length (500m)
- Conductor cross-section: 150 mm²
- Number of aluminium wires: 37
- Conductor diameter: 14.3 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 19.5 mm
- Approximate weight: 520 kg/km
185mm2
Nexans ref. 52181
- Packaging: Cut to length (500m)
- Conductor cross-section: 185 mm²
- Number of aluminium wires: 37
- Conductor diameter: 16.0 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 21.5 mm
- Approximate weight: 635 kg/km
240mm2
Nexans ref. 43504
- Packaging: Cut to length (500m)
- Conductor cross-section: 240 mm²
- Number of aluminium wires: 37
- Conductor diameter: 18.4 mm
- Nominal insulation thickness: 2.4 mm
- Outer Diameter: 24 mm
- Approximate weight: 805 kg/km
300mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Number of aluminium wires: 37
- Conductor diameter: 20.7 mm
- Nominal insulation thickness: 2.8 mm
- Outer Diameter: 27 mm
- Approximate weight: 1025 kg/km
400mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 400 mm²
- Number of aluminium wires: 61
- Conductor diameter: 23.4 mm
- Nominal insulation thickness: 2.8 mm
- Outer Diameter: 29.5 mm
- Approximate weight: 1280 kg/km
500mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 500 mm²
- Number of aluminium wires: 61
- Conductor diameter: 26.6 mm
- Nominal insulation thickness: 2.8 mm
- Outer Diameter: 33 mm
- Approximate weight: 1610 kg/km
Description
Description
Standards
-
ProductABNT NBR 7285/01
Application
The no-covered insulated cables are recommended for power supply circuits and power distribution in industrial, commercial and residential buildings.
Manufacturing Data
1) Conductor
Aluminium strands, class 2 stranding.
2) Insulation
Cross-linked Polyethylene (XLPE), for 90°C, black color.
Voltage Class:
0,6/1kV
Operating Temperature:
Normal operation: 90°C, Overload: 130°C, Short-circuit: 250°C
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania