- Markets
- Products
- Services and Solutions
- About Nexans
- People and Carreer
- News
- Certificates and Documents
- Nexans Insights
- Search
- Contact us
- Compare
- Sign in
PVC covered XLPE-insulated Aluminium Cables - 3 conductors
PVC covered XLPE-insulated Aluminium Cables - 3 conductors
The PVC covered XLPE-insulated aluminium cable is constituted by a compact or a non compact round conductor, composed by aluminium strands, with a cross-linked (XLPE) insulated and with PVC covered.
Read more10mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 10 mm²
- Number of aluminium wires: 7
- Conductor diameter: 4.1 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.2 mm
- Outer Diameter: 16 mm
- Approximate weight: 300 kg/km
16mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Number of aluminium wires: 7
- Conductor diameter: 4.7 mm
- Nominal insulation thickness: 0.7 mm
- Protective Covering Nominal Thickness: 1.3 mm
- Outer Diameter: 17.5 mm
- Approximate weight: 385 kg/km
25mm2
Nexans ref. 52917
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Number of aluminium wires: 7
- Conductor diameter: 5.9 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Outer Diameter: 21 mm
- Approximate weight: 565 kg/km
35mm2
Nexans ref. 52168
- Packaging: Cut to length (500m)
- Conductor cross-section: 35 mm²
- Number of aluminium wires: 7
- Conductor diameter: 7.0 mm
- Nominal insulation thickness: 0.9 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 23.5 mm
- Approximate weight: 725 kg/km
50mm2
Nexans ref. 52214
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Number of aluminium wires: 19
- Conductor diameter: 8.1 mm
- Nominal insulation thickness: 1.0 mm
- Protective Covering Nominal Thickness: 1.6 mm
- Outer Diameter: 27 mm
- Approximate weight: 955 kg/km
70mm2
Nexans ref. 52215
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Number of aluminium wires: 19
- Conductor diameter: 9.8 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.7 mm
- Outer Diameter: 31.5 mm
- Approximate weight: 1300 kg/km
95mm2
Nexans ref. 52219
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Number of aluminium wires: 19
- Conductor diameter: 11.5 mm
- Nominal insulation thickness: 1.1 mm
- Protective Covering Nominal Thickness: 1.8 mm
- Outer Diameter: 35.5 mm
- Approximate weight: 1670 kg/km
120mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Number of aluminium wires: 37
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 1.2 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Outer Diameter: 39.5 mm
- Approximate weight: 2110 kg/km
150mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Number of aluminium wires: 37
- Conductor diameter: 14.3 mm
- Nominal insulation thickness: 1.4 mm
- Protective Covering Nominal Thickness: 2.1 mm
- Outer Diameter: 44 mm
- Approximate weight: 2590 kg/km
185mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Number of aluminium wires: 37
- Conductor diameter: 16.0 mm
- Nominal insulation thickness: 1.6 mm
- Protective Covering Nominal Thickness: 2.2 mm
- Outer Diameter: 49 mm
- Approximate weight: 3200 kg/km
240mm2
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Number of aluminium wires: 37
- Conductor diameter: 18.4 mm
- Nominal insulation thickness: 1.7 mm
- Protective Covering Nominal Thickness: 2.4 mm
- Outer Diameter: 55 mm
- Approximate weight: 4060 kg/km
Description
Description
Standards
-
ProductABNT NBR 7287/92
Application
The covered insulated cables are recommended for power supply circuits and power distribution ranging from substations and large-size industrial sites to small commercial buildings.
Manufacturing Data
1) Conductor
Aluminium strands, class 2 stranding.
2) Insulation
Cross-linked Polyethylene (XLPE), for 90°C.
3) Identification
The conductors are identified by colors white, blue and black.
Voltage Class:
0,6/1kV
Operating Temperature:
Normal operation: 90°C, Overload: 130°C, Short-circuit: 250°C
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania