Nexans EPR105-PVC 12/20kV
Nexans EPR105-PVC 12/20kV
Nexans EPR105-PVC cable (formerly EP-DRY 105) is a medium voltage cable, from 3.6/6 kV to 20/35 kV. Its main feature is its EPR 105 composite insulation, which allows it to operate at a temperature of up to 105ºC at steady state, resulting in a higher current carrying capacity. It has a PVC sheath (ST2), copper conductor, stranded class 2, compacted type.
Read moreNexans EPR105-PVC 12/20kV 1x25mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.76 mm
- Nominal insulation thickness: 4.7 mm
- Diameter over insulation: 17.0 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 22.5 mm
- Approximate weight: 713 kg/km
Nexans EPR105-PVC 12/20kV 1x35mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.82 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 16.5 mm
- Protective Covering Nominal Thickness: 1.4 mm
- Outer Diameter: 22 mm
- Approximate weight: 746 kg/km
Nexans EPR105-PVC 12/20kV 1x50mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.18 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 18.0 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 23.5 mm
- Approximate weight: 901 kg/km
Nexans EPR105-PVC 12/20kV 1x70mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.7 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 19.5 mm
- Protective Covering Nominal Thickness: 1.5 mm
- Outer Diameter: 25 mm
- Approximate weight: 1127 kg/km
Nexans EPR105-PVC 12/20kV 1x95mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.3 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 21.0 mm
- Protective Covering Nominal Thickness: 1.6 mm
- Outer Diameter: 27 mm
- Approximate weight: 1409 kg/km
Nexans EPR105-PVC 12/20kV 1x120mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.6 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 22.5 mm
- Protective Covering Nominal Thickness: 1.6 mm
- Outer Diameter: 28.5 mm
- Approximate weight: 1653 kg/km
Nexans EPR105-PVC 12/20kV 1x150mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 24.0 mm
- Protective Covering Nominal Thickness: 1.7 mm
- Outer Diameter: 30.5 mm
- Approximate weight: 1960 kg/km
Nexans EPR105-PVC 12/20kV 1x185mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 185 mm²
- Conductor diameter: 15.58 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 25.5 mm
- Protective Covering Nominal Thickness: 1.7 mm
- Outer Diameter: 31.5 mm
- Approximate weight: 2283 kg/km
Nexans EPR105-PVC 12/20kV 1x240mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.0 mm
- Nominal insulation thickness: 4.5 mm
- Diameter over insulation: 29.0 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Outer Diameter: 35.5 mm
- Approximate weight: 2969 kg/km
Nexans EPR105-PVC 12/20kV 1x300mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.4 mm
- Nominal insulation thickness: 4.5 mm
- Diameter over insulation: 31.5 mm
- Protective Covering Nominal Thickness: 1.9 mm
- Outer Diameter: 38 mm
- Approximate weight: 3598 kg/km
Nexans EPR105-PVC 12/20kV 1x400mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 400 mm²
- Conductor diameter: 22.6 mm
- Nominal insulation thickness: 4.5 mm
- Diameter over insulation: 33.5 mm
- Protective Covering Nominal Thickness: 2 mm
- Outer Diameter: 40.5 mm
- Approximate weight: 4402 kg/km
Nexans EPR105-PVC 12/20kV 1x500mm2
Nexans ref.
- Number of cores: 1
- Conductor cross-section: 500 mm²
- Conductor diameter: 25.9 mm
- Nominal insulation thickness: 4.5 mm
- Diameter over insulation: 37.0 mm
- Protective Covering Nominal Thickness: 2.1 mm
- Outer Diameter: 44 mm
- Approximate weight: 5491 kg/km
Nexans EPR105-PVC 12/20kV 3x25mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.76 mm
- Nominal insulation thickness: 4.7 mm
- Diameter over insulation: 17.0 mm
- Protective Covering Nominal Thickness: 2.3 mm
- Outer Diameter: 47 mm
- Approximate weight: 2560 kg/km
Nexans EPR105-PVC 12/20kV 3x35mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.82 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 16.5 mm
- Protective Covering Nominal Thickness: 2.3 mm
- Outer Diameter: 46 mm
- Approximate weight: 2698 kg/km
Nexans EPR105-PVC 12/20kV 3x50mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.18 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 18.0 mm
- Protective Covering Nominal Thickness: 2.3 mm
- Outer Diameter: 49 mm
- Approximate weight: 3378 kg/km
Nexans EPR105-PVC 12/20kV 3x70mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.7 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 19.5 mm
- Protective Covering Nominal Thickness: 2.4 mm
- Outer Diameter: 53 mm
- Approximate weight: 3830 kg/km
Nexans EPR105-PVC 12/20kV 3x95mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.3 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 21.0 mm
- Protective Covering Nominal Thickness: 2.6 mm
- Outer Diameter: 57 mm
- Approximate weight: 5200 kg/km
Nexans EPR105-PVC 12/20kV 3x120mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.6 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 22.5 mm
- Protective Covering Nominal Thickness: 2.7 mm
- Outer Diameter: 60 mm
- Approximate weight: 5941 kg/km
Nexans EPR105-PVC 12/20kV 3x150mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 24.0 mm
- Protective Covering Nominal Thickness: 2.8 mm
- Outer Diameter: 64 mm
- Approximate weight: 6809 kg/km
Nexans EPR105-PVC 12/20kV 3x185mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Conductor diameter: 15.58 mm
- Nominal insulation thickness: 4.0 mm
- Diameter over insulation: 25.5 mm
- Protective Covering Nominal Thickness: 2.9 mm
- Outer Diameter: 67 mm
- Approximate weight: 8212 kg/km
Nexans EPR105-PVC 12/20kV 3x240mm2
Nexans ref.
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.0 mm
- Nominal insulation thickness: 4.5 mm
- Diameter over insulation: 29.0 mm
- Protective Covering Nominal Thickness: 3.1 mm
- Outer Diameter: 75 mm
- Approximate weight: 10442 kg/km
Description
Description
Standards
-
ProductABNT NBR 6251 ; ABNT NBR 7286 ; ABNT NBR NM 280
-
InstallationABNT NBR 14039
Application
Nexans EPR105-PVC cables are ideal for applications in insulated power supply and distribution circuits in substations, industrial and commercial installations. They can be installed in a wide variety of conditions, including outdoors, in ducts, raceways, underground installations, duct banks or trays. Compared to conventional cables insulated with EPR, HEPR or XLPE, which have a maximum conductor temperature of 90°C, Nexans EPR105-PVC cables can operate with a continuous conductor temperature of up to 105°C, resulting in higher current carrying capacity. In addition, they have a coordinated insulation thickness according to NBR 6251, resulting in reduced external dimensions compared to conventional EPR, HEPR or XLPE insulated cables.
Construction
1.Conductor: Formed by bare copper wires, minimum conductivity 100% IACS, soft quenching, compacted stranding class 2 compliant.
2.Conductor shielding: Extruded semi-conductor thermosetting compound.
3.Insulation: Thermosetting ethylene propylene rubber compound (EPR 105) for an operating temperature at the conductor of 105 °C, meeting the physical requirements prescribed by NBR 6251.
4.Insulating shielding: Non-metallic shielding based on extruded semi-conductive thermosetting compound, easily removed when cold and manufactured using a triple extrusion process and a nitrogen dry curing system.
5.Metallic shielding: Consisting of copper wires, helically applied to the insulating shielding, with a minimum cross-section of 6 mm2 according to NBR 6251. For different shielding sections, please consult in advance.
6.Sheath: Polyvinyl chloride (PVC) thermoplastic compound, black colour, complying with the physical requirements prescribed by NBR 6251, type ST2.
Identification:
Supplied in black colour with sequential marking of the footage.
Operation regime:
Thermal limits in operating conditions are in accordance with ABNT NBR 6251.
Permanent regime: 105ºC
Overload regime: 140ºC
Short-circuit rating: 250ºC
Note:
- Dimensions and parameters determined on the basis of nominal values, therefore subject to the tolerances laid down in the specifications and manufacturing variations.
- All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans, being subject to a systemic revision or update without any formal or previous communication, following the referenced standards.
Important:
1) OWNERSHIP OF TECHNICAL DOCUMENTATION: Ownership of drawings, plans, manuals, diagrams, schematics, information, documents, etc. relating to the products offered or supplied to the customer belongs to, and shall remain with, Nexans. Should the customer receive a copy of such documents, the customer agrees not to use such drawings or other documents without the prior express written authorization of Nexans.
2) CONFIDENTIALITY: The customer shall not disclose information relating to this technical documentation to third parties without Nexans' prior written permission, nor use such information for purposes other than those related to the execution of the proposal (if accepted). Without prejudice to the above, Nexans may disclose information to third parties that are part of the same economic group as Nexans, for the purposes of executing this proposal, if necessary.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania