Energyflex BR Afitox 120° (Cu) Cables - 0.6/1 kV

Products

ENERGYFLEX AFITOX 120° 0,6/1kV 1x120mm2 NEW

Nexans ref. 48434

  • Packaging: Reel
  • Conductor cross-section: 120 mm²
  • Conductor diameter: 14.68 mm
  • Nominal insulation thickness: 1.2 mm
  • Protective Covering Nominal Thickness: 1.3 mm
  • Outer Diameter: 20.5 mm
  • Approximate weight: 1180 kg/km
  • Inductive reactance: 0.0779 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.209 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.211 Ohm/km
  • Voltage Drop: 0.37 V/A.km
  • DC permissible current rating: 437 A
  • Perm. current rating in air 30°C - trefoil formation: 383 A

ENERGYFLEX AFITOX 120° 0,6/1kV 1x185mm2 NEW

Nexans ref. 51309

  • Packaging: Reel
  • Conductor cross-section: 185 mm²
  • Conductor diameter: 18.39 mm
  • Nominal insulation thickness: 1.6 mm
  • Protective Covering Nominal Thickness: 1.6 mm
  • Outer Diameter: 26 mm
  • Approximate weight: 1808 kg/km
  • Inductive reactance: 0.0806 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.108 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.138 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.14 Ohm/km
  • Voltage Drop: 0.27 V/A.km
  • DC permissible current rating: 575 A
  • Perm. current rating in air 30°C - trefoil formation: 510 A

ENERGYFLEX AFITOX 120° 0,6/1kV 1x2.5mm2 NEW

Nexans ref. 30580

  • Packaging: Reel (m)
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.97 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 0.8 mm
  • Outer Diameter: 5.5 mm
  • Approximate weight: 43 kg/km
  • Inductive reactance: 0.1255 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 8.21 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 10.469 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 10.469 Ohm/km
  • Voltage Drop: 14.64 V/A.km
  • DC permissible current rating: 37 A
  • Perm. current rating in air 30°C - trefoil formation: 29 A

ENERGYFLEX AFITOX 120° 0,6/1kV 1x6mm2 NEW

Nexans ref. 40023

  • Packaging: Reel
  • Conductor cross-section: 6 mm²
  • Conductor diameter: 2.95 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 0.8 mm
  • Outer Diameter: 6.5 mm
  • Approximate weight: 74 kg/km
  • Inductive reactance: 0.114 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 4.323 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 4.323 Ohm/km
  • Voltage Drop: 6.11 V/A.km
  • DC permissible current rating: 65 A
  • Perm. current rating in air 30°C - trefoil formation: 53 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x10mm2 NEW

Nexans ref. 44118

  • Packaging: Reel
  • Conductor cross-section: 10 mm²
  • Conductor diameter: 3.92 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 0.8 mm
  • Outer Diameter: 7.5 mm
  • Approximate weight: 116 kg/km
  • Inductive reactance: 0.0994 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 2.486 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 2.486 Ohm/km
  • Voltage Drop: 3.55 V/A.km
  • DC permissible current rating: 90 A
  • Perm. current rating in air 30°C - trefoil formation: 74 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x150mm2 NEW

Nexans ref. 41541

  • Packaging: Reel
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 16.23 mm
  • Nominal insulation thickness: 1.4 mm
  • Protective Covering Nominal Thickness: 1.4 mm
  • Outer Diameter: 22.5 mm
  • Approximate weight: 1477 kg/km
  • Inductive reactance: 0.0819 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.132 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.168 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.17 Ohm/km
  • Voltage Drop: 0.32 V/A.km
  • DC permissible current rating: 504 A
  • Perm. current rating in air 30°C - trefoil formation: 444 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x16mm2 NEW

Nexans ref. 48895

  • Packaging: Reel
  • Conductor cross-section: 16 mm²
  • Conductor diameter: 4.93 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 0.9 mm
  • Outer Diameter: 8.5 mm
  • Approximate weight: 183 kg/km
  • Inductive reactance: 0.0918 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 1.24 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 1.581 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 1.581 Ohm/km
  • Voltage Drop: 2.29 V/A.km
  • DC permissible current rating: 121 A
  • Perm. current rating in air 30°C - trefoil formation: 101 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x240mm2 NEW

Nexans ref. 45222

  • Packaging: Reel
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 20.35 mm
  • Nominal insulation thickness: 1.7 mm
  • Protective Covering Nominal Thickness: 1.7 mm
  • Outer Diameter: 28.5 mm
  • Approximate weight: 2307 kg/km
  • Inductive reactance: 0.08 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.0817 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.1042 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.108 Ohm/km
  • Voltage Drop: 0.23 V/A.km
  • DC permissible current rating: 679 A
  • Perm. current rating in air 30°C - trefoil formation: 607 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x35mm2 NEW

Nexans ref. 45097

  • Packaging: Reel
  • Conductor cross-section: 35 mm²
  • Conductor diameter: 7.46 mm
  • Nominal insulation thickness: 0.9 mm
  • Protective Covering Nominal Thickness: 1.1 mm
  • Outer Diameter: 12 mm
  • Approximate weight: 378 kg/km
  • Inductive reactance: 0.0846 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.565 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.720 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.721 Ohm/km
  • Voltage Drop: 1.09 V/A.km
  • DC permissible current rating: 200 A
  • Perm. current rating in air 30°C - trefoil formation: 169 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x4mm3 NEW

Nexans ref. 57188

  • Packaging: Reel
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.45 mm
  • Nominal insulation thickness: 0.7 mm
  • Protective Covering Nominal Thickness: 0.8 mm
  • Outer Diameter: 6 mm
  • Approximate weight: 59 kg/km
  • Inductive reactance: 0.1223 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 6.490 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 6.49 Ohm/km
  • Voltage Drop: 9.12 V/A.km
  • DC permissible current rating: 50 A
  • Perm. current rating in air 30°C - trefoil formation: 40 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x50mm2 NEW

Nexans ref. 31465

  • Packaging: Reel
  • Conductor cross-section: 50 mm²
  • Conductor diameter: 9.31 mm
  • Nominal insulation thickness: 1.0 mm
  • Protective Covering Nominal Thickness: 1.2 mm
  • Outer Diameter: 14.5 mm
  • Approximate weight: 525 kg/km
  • Inductive reactance: 0.0814 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.393 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.501 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.502 Ohm/km
  • Voltage Drop: 0.78 V/A.km
  • DC permissible current rating: 242 A
  • Perm. current rating in air 30°C - trefoil formation: 207 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x70mm2 NEW

Nexans ref.

  • Packaging: Reel
  • Conductor cross-section: 70 mm²
  • Conductor diameter: 10.8 mm
  • Nominal insulation thickness: 1.1 mm
  • Protective Covering Nominal Thickness: 1.2 mm
  • Outer Diameter: 19 mm
  • Approximate weight: 720 kg/km
  • Inductive reactance: 0.079 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.277 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.353 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.353 Ohm/km
  • Voltage Drop: 0.57 V/A.km
  • DC permissible current rating: 310 A
  • Perm. current rating in air 30°C - trefoil formation: 268 A

ENERGYFLEX AFITOX 120° 0.6/1kV 1x95mm2 NEW

Nexans ref. 37405

  • Packaging: Reel
  • Conductor cross-section: 95 mm²
  • Conductor diameter: 12.74 mm
  • Nominal insulation thickness: 1.1 mm
  • Protective Covering Nominal Thickness: 1.3 mm
  • Outer Diameter: 18.5 mm
  • Approximate weight: 948 kg/km
  • Inductive reactance: 0.0764 Ohm/km
  • Max. DC resistance of the conductor at 20°C: 0.21 Ohm/km
  • Maximum DC resistance of the conductor at 90°C: 0.268 Ohm/km
  • Max. Electrical Resistance AC 60Hz 90°C: 0.269 Ohm/km
  • Voltage Drop: 0.45 V/A.km
  • DC permissible current rating: 377 A
  • Perm. current rating in air 30°C - trefoil formation: 328 A

Description

Description

Application

Flexible cables for photovoltaic installation in DC system, with the benefits of the tinned copper conductor that ensure a high performance connections, even in severe environmental conditions (moisture and sunlight exposure, vibrations,...) that when asscioated to be a double covered layer of a crosslinked and high temperature compounds allows its use in temperature ambient or surround the cables up to 90°C, giving a temperature gradient minimum to the current capacity without compromise the mechanical and electrical characteristics of the cable during its life time, being recommended to the installation of the connections of the photovoltaic panels and similar applications where the cable will be exposure to certain period at high ambient or surround temperatures.

To comply the particular requirements of UV resistant and the flame retardant, these cables are supplied with a special outer sheath compound formulated wih special additives in compliance to be approved in the performance following the international standards UL 2556 e IEC 60332-1. 

 

  1. Conductor: Extra-flexible stranded tinned copper wires, class 5, as per NBR NM 280 and IEC 60228;
  2. Insulation: Continuous layer of extruded crosslinked compound based on halogen free polymer type XLPO/elastomer, for 90°C continuous temperatureoperation at the conductor and 120°C for 20000h;
  3. Outer Sheath: Continuous layer of extruded crosslinked compound formulated based on halogen free polymer, with special characteristics to comply the requirements of flame retardant, UV resistant, low toxicity and low smoke index - halogen free.

 

Reference Standard

International:

  • IEC 62930

  • EN 50618

  • TÜV  2 Pfg 1169

​National:  

  • ABNT NBR 16612
  • ABNT NBR 5410

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tinned annealed copper

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible

Usage characteristics

Usage characteristics

Bending factor when laying
4 (xD)
Fire resistant
IEC 60332-1
Max. conductor temperature in service
120 °C
U.V resistance
Yes
Weather resistance
Yes

Resources

Resources

Documentation

xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close