Description
Standards
National : ABNT NBR 9889Description
Construction: Soft annealed bare copper conductor, 0.40 , 0.50 , 0.65 or 0.90mm nominal diameter, insulated with colored solid polyethylene. The insulated conductors are twisted in pairs and assembled in layers and/or groups to form a substantially cylindrical core. The cable core is bound with binder threads and/or a binder polyester tape and shielded by a flat polyethylene-clad aluminium tape (LAP - Laminated Aluminium Polyethylene), longitudinally applied. A black polyethylene jacket is extruded over the shield and the steel messenger. Under the jacket, two ripcords are applied to ease the jacket removal. Service pairs may be available, according to the Brazilian Standard ABNT/NBR 9889, upon customer request.
Application: These cables are intended for analogical or digital signal transmissions.
Installation: Aerial self-supported.
Characteristics
Construction characteristics | |
---|---|
Conductor material | Bare annealed copper stranded |
Insulation | Solid polyethylene |
Screen | LAP tape |
Messenger | HS 7 x 1,57mm |
Outer sheath | Polyethylene |
Construction type | 40/10 |
Dimensional characteristics | |
Conductor diameter | 0.4mm |
Messenger conductor diameter | 4.8mm |
Number of pairs | 10 |
Approximate weight | 250kg/km |
Electrical characteristics | |
Mutual capacitance, range | 46.0 .. 56.0nF/km |
Maximum average unbalance capacitance pair-to-pair | 45.3pF/km |
Max. DC resistance of the conductor at 20°C | 147.2Ohm/km |
Resistance unbalance DC max % of loop resistance | 2% |
Maximum unbalance capacitance pair-to-pair | 181pF/km |
Maximum individual DC resistance unbalance | 5% |
Maximum average unbalance capacitance pair-to-ground | 574pF/km |
Maximum unbalance capacitance pair-to-ground | 2625pF/km |
Minimum insulation resistance | 15000MOhm.km |
Test voltage AC at 50hz conductor /conductor | 2500V |
Test voltage AC at 50hz conductor/screen | 10000V |
Transmission characteristics | |
Attenuation, max. at 150 kHz | 12.5dB/km |
Attenuation, max. average at 1024 kHz | 29.5dB/km |
NEXT, minimum individual at 150 kHz | 53.0dB |
NEXT, minimum individual at 1024 kHz | 40.0dB |
ELFEXT, minimum average at 150 kHz | 68.0dB/km |
ELFEXT, minimum individual at 150 kHz | 58.0dB/km |
ELFEXT, minimum average at 1024 kHz | 52.0dB/km |
ELFEXT, minimum individual at 1024 kHz | 35.0dB/km |
Usage characteristics | |
U.V resistance | Yes |
Packaging | Reel |
Length | 1000m |
Docs and info
Related documents
Selling information
Sheath marking:
NEXANS YYYY CTP-APL-AS DD/XXX OP-ZZZZZ LLLL
Where:
YYYY = Year of manufacturing;
DD = Conductor nominal diameter;
XXX = Pair count;
ZZZZZ = Purchase order;
LLLL = Metric length (m)
The marking is made on the jacket, at each meter, along the cable axis.