Description
Standards
National : ABNT NBR 6251 ; ABNT NBR 7287 ; ABNT NBR NM 280Description
The FIPEX BF cables are used in power supply circuits and distribution enrgía in substations, industrial and commercial facilities and can be istalados outdoors, in ducts, channels, directly buried in the ground, bank ducts or trays.
Constructive description
- Condutor aluminum: Class 2
- Conductor shield: thermoset compound semiconductor
- Insulation: Composed of thermosetting Cross-linked Polyethylene (XLPE) for operating temperature of 90 ° C conductor, meeting the physical requirements perscritos by NBR 6251
- Insulation shield : non-metallic shield to the base compound semiconductor thermoset and metal shield on bare copper wires, annealed, aplecadoshelicoidalmente with nominal section of 6 mm²
- Coverage: Polyvinyl thermoplastic compound chloride (PVC) in black, taking into account physical requirements prescribed by NBR 6251 type ST2
Notes
- Identification of conductors: three-pole cable in the identification of the phases is made by means of narrow ribbon white, black and red, veins and marking applied on Phase A, Phase B and Phase C on the cover
- Section of the metal shield: for shielded cables section than 6 mm² due to particular conditions of short circuit Terra Phase X or in the case of tinned copper wires, should be asked specific cable design.
- Installation in conduits: we recommend a preliminary study of the occupancy rate and duct mateial, including induction effects when metal.
Maximum conductor temperatures
90 °C in continuous service
130 °C overcharging
250 °C shorted
Specifications
NBR 7287 - Power cables with extruded insulation of cross-linked polyethylene (XLPE) for voltages of 1 kV to 35 kV - Performance requirements.
NBR NM 280 - Conductors of insulated cables.
NBR 6251 - Power cables with extruded insulation for rated voltages from 1 kV to 35 kV - building requirements
Characteristics
Construction characteristics | |
---|---|
Conductor material | Aluminum |
Dimensional characteristics | |
Number of cores | 1 |
Conductor cross-section | 150mm² |
Conductor diameter | 14.3mm |
Nominal insulation thickness | 6.8mm |
Diameter over insulation | 30.0mm |
Protective Covering Nominal Thickness | 1.9mm |
Outer Diameter | 36.5mm |
Approximate weight | 1341kg/km |
Mechanical characteristics | |
Mechanical resistance to impacts | Good |
Usage characteristics | |
Bending factor when laying | 12(xD) |
Fire resistant | IEC 60332-1 |
Ambient installation temperature, range | -5 .. 60°C |
Weather resistance | Good |
Max. conductor temperature in service | 90°C |
Overload maximum core temperature | 130°C |
Short-circuit max. conductor temperature | 250°C |
Docs and info
Current carrying capacity for rated voltage of 15/25 kV |
Conductors in open air - conductor temperature: 90°C - Ambient temperature: 30°C |
![]() |
In tray | 402 |
![]() |
In tray | 348 | |
![]() |
In tray | 348 |
![]() |
Cable trunking | 330 | |
![]() |
Cable trunking | 299 |
![]() |
Cable trunking | 299 | |
![]() |
In conduit | 248 |
![]() |
In conduit | 248 | |
![]() |
In conduit | 248 |
Current carrying capacity for rated voltage of 15/25 kV |
Conductors directly in the ground; Conductor temperature: 90° C; Ambient temperature: 20 °C; Soil thermal resistivity: 2,5 k.m/W |
![]() |
In duct bank | 213 |
![]() |
In duct bank | 183 | |
![]() |
In duct bank | 183 |
![]() |
Cables direct in the ground | 246 | |
![]() |
Cables direct in the ground | 216 |
![]() |
Cables direct in the ground | 216 |