Description
For fixed installation in all areas on board ship.
Standards
International : IEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376; IEC 60332-1; IEC 60332-3-22 Cat.A; IEC 60754-1; IEC 60754-2; IEC 61034-1/2Description
Construction
- Conductor: stranged annealed tinned copper wires class 2; IEC 60228; each core made up of 7 stranded copper wires;
- Insulation: HF XLPE halogen free crosslinked polyethylene;
- Shield: individual shield of aluminium/polyester tape (0,065mm thick) with stranded tinned copper drain conductor 0,5mm² (7wires);
- Separator: polyester tape;
- Armour/Shield: plain copper wire braid (without additional drain wire);
- Outer Sheath: grey thermoplastic polyolefin halogen free compound (SHF1).
Identification of Cores:
pair - black and white coloured insulation; each pair with printed numbers.
Assembly of Cores: twisted pairs (cabled with fillers where necesary to make round).
Routine Tests:
- electrical resistance of conductor;
- electric voltage;
- insulation resistance referred to 20°C.
Packing: wood reels in accordance with the terms of NBR 11137.
Tolerance: thickness and dimensions are considered as nominal values, subject to industry tolerance.
Minimum Bending Radius: values according to nominal outside diameter. During installation, must be used eight times the measured diameter.
This product is part of our Shiplink® offer.
Characteristics
Construction characteristics | |
---|---|
Conductor shape | RN |
Dimensional characteristics | |
Number of pairs | 10 |
Conductor cross-section | 0.75mm² |
Number of round wires | 7 |
Conductor diameter | 1.11mm |
Nominal insulation thickness | 0.7mm |
Protective Covering Nominal Thickness | 1.5mm |
Outer Diameter | 25.5mm |
Approximate weight | 825kg/km |
Usage characteristics | |
Max. conductor temperature in service | 90°C |
Short-circuit max. conductor temperature | 250°C |
Minimum static operating bending radius | 204mm |
Docs and info
Selling information
T: Triad
RN: Non Compacted Round Stranded