Nexans XLPE-SHF1 AL 0,6/1kV
Certifications and labels
Nexans XLPE-SHF1 AL 0,6/1kV
Nexans XLPE-SHF1 AL 0.6/1 kV cable allows you to raise the standard of your electrical installations. It offers superior protection with resistance to ultraviolet radiation and to the spread of fire, and non-halogenated composition, ensuring a safer environment, a superior choice for those seeking efficiency and safety. Class 2 compact round stranded aluminium conductor, insulated in high-quality XLPE and protected by an ST8 (SHF1) jacket, this cable is designed to withstand the most demanding conditions. With a thermal capacity of up to 90°C and a voltage of 0.6/1 kV, it is perfectly suited to a Data Centers and wide range of industrial and construction applications. It is particularly suitable for environments with a high concentration of people. It is available in sections from 25 mm² to 500 mm². See technical details below:
Read moreNexans XLPE-SHF1 AL 0.6/1kV 1x25mm2
Nexans ref. 45492
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.92 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Outer Diameter: 11 mm
- Approximate weight: 154.4 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x35mm2
Nexans ref. 41408
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.91 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Outer Diameter: 12 mm
- Approximate weight: 189.1 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x50mm2
Nexans ref. 41414
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.05 mm
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
- Outer Diameter: 13.5 mm
- Approximate weight: 233.3 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x70mm2
Nexans ref. 48752
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.7 mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.4 mm
- Outer Diameter: 15.5 mm
- Approximate weight: 316.4 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x95mm2
Nexans ref. 59565
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.31 mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.5 mm
- Outer Diameter: 17 mm
- Approximate weight: 404.3 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x120mm2
Nexans ref. 41003
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.95 mm
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 1.5 mm
- Outer Diameter: 19 mm
- Approximate weight: 503.8 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x150mm2
Nexans ref. 41004
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 1.6 mm
- Outer Diameter: 21 mm
- Approximate weight: 607.7 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x185mm2
Nexans ref. 41007
- Conductor cross-section: 185 mm²
- Conductor diameter: 15.8 mm
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 1.6 mm
- Outer Diameter: 23 mm
- Approximate weight: 728.2 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x240mm2
Nexans ref. 44211
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.0 mm
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 1.7 mm
- Outer Diameter: 26 mm
- Approximate weight: 931.1 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x300mm2
Nexans ref. 47197
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.1 mm
- Nominal insulation thickness: 1.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Outer Diameter: 28.5 mm
- Approximate weight: 1166 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x400mm2
Nexans ref. 28953
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.1 mm
- Nominal insulation thickness: 2.0 mm
- Nominal outer sheath thickness: 1.9 mm
- Outer Diameter: 32.5 mm
- Approximate weight: 1452 kg/km
Nexans XLPE-SHF1 AL 0.6/1kV 1x500mm2
Nexans ref. 30166
- Conductor cross-section: 500 mm²
- Conductor diameter: 26.4 mm
- Nominal insulation thickness: 2.2 mm
- Nominal outer sheath thickness: 2.0 mm
- Outer Diameter: 36.5 mm
- Approximate weight: 1827 kg/km
Description
Description
Standards
-
ProductABNT NBR NM 280; IEC 60228; IEC 60502-1
-
InstallationABNT NBR 5410
-
TestABNT NBR NM-IEC 60332-3-24
Application:
Nexans XLPE-SHF1 AL 0.6/1 kV cables have fire-retardant characteristics combined with low emissions of smoke and toxic gases - the greatest risks in a fire. They are particularly suitable for buildings such as Data Centers.
Construction:
- Conductor: Formed from compacted round aluminum wires, class 2, according to IEC 60228.
- Insulation: Composed of thermosetting Cross-linked Polyethylene (XLPE) for operating temperature of 90 ° C conductor.
- Outer Sheath: Non-halogenated thermoplastic compound, type ST8 (SHF1), UV resistant, black color.
Identification:
Note: Other colors can be evaluated on request.
Operating regime:
The thermal limits under operating conditions:
Permanent regime: 90ºC
Overload regime: 130ºC
Short-circuit regime: 250ºC
Note:
- Dimensions and parameters determined on the basis of nominal values, therefore subject to the tolerances laid down in the specifications and manufacturing variations.
- All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans, being subject to a systemic revision or update without any formal or previous communication, following the referenced standards.
Important:
1) OWNERSHIP OF TECHNICAL DOCUMENTATION: Ownership of drawings, plans, manuals, diagrams, schematics, information, documents, etc. relating to the products offered or supplied to the customer belongs to, and shall remain with, Nexans. Should the customer receive a copy of such documents, the customer agrees not to use such drawings or other documents without the prior express written authorization of Nexans.
2) CONFIDENTIALITY: The customer shall not disclose information relating to this technical documentation to third parties without Nexans' prior written permission, nor use such information for purposes other than those related to the execution of the proposal (if accepted). Without prejudice to the above, Nexans may disclose information to third parties that are part of the same economic group as Nexans, for the purposes of executing this proposal, if necessary.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania