Sobre a Nexans
Produtos e Soluções
Serviço ao Cliente
Trabalhe na Nexans
Notícias e Imprensa
Applications
Flexible cable with emergency operating features for inner wiring in railway vehicles (locomotives, trains, trolley busses), switching stations and control panels. Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4. Serves request acc. to EN 45545-1. Circuit integrity acc. to EN 50200 (15 minutes) resp. EN 50362.
1. Conductor
Flexible stranded tinned copper, class 5 acc. to DIN VDE 0295 / IEC 60228 / HD 383.
2. Minerally conductor taping
3. Insulation
Double layer insolation type EI110/EI109 (EM104) acc. to EN 50264-1, oil, diesel-oil, ozone and uv resistant.
e.g.: RHEYHALON (N)MHXAFOE-FR 0,6/1 kV EN 50264-3-1 600V 0,5 M FA-Nr. ...
Black (BK); green/yellow (GNYE); other colours on request
DIN 5510 part 1:, flame protection class 1, 2, 3 and 4 BS 6853 (on request)
Max. operating voltage (d.c.)
Vo =500 or 1500V
Conductor at normal operation
≤ 90 °C/250.000 h
≤ 120 °C/20.000 h
Overload
≤ 160 °C / 50 h
Conductor under short-circuit conditions (tinned)
≤ 200 °C
Other cross-sections on request.
Special conditions relating temperature and bending radii (e.g. by compelled guidance into cluthes, wagontransition and boogies) on request.